Drip Irrigation Calculator

Work out how many emitters (or feet of dripline) a drip zone needs, how much water it draws in GPH and GPM, how fast it applies water, and whether your supply can run it as one zone. Use it for plants with their own emitters, beds and crop rows with dripline or tape, or micro-sprays.

Drip irrigation calculator

Choose your drip layout
Quick picks

1Plants and emitters

Not sure? Work it out from soil and canopy.

GPH

2Supply check (optional)

GPM

Add it to check the zone fits. Measure it with a bucket test.

%

Share of the supply you plan to use; 80 % keeps pressure steady.

See your drip zone ↓

How the calculator works

A drip zone is a set of emitters (also called drippers) on one valve. This calculator counts them, adds up their flow and checks that your water supply can feed them all at once.

Pick the layout that matches your garden. Plants is for shrubs, trees and pots with their own emitters. Dripline is for beds and crop rows with inline dripline or drip tape (inline drip pipe). Micro-spray is for small sprayers and jets that wet a circle.

  • Plantsemitters = plants × emitters per plant · flow (GPH) = emitters × emitter GPH
  • Dripline rowsrows = ⌈bed width ÷ row spacing⌉ · emitters per row = ⌊row length ÷ emitter spacing⌋
  • Footagedripline = rows × row length (the header across the bed is separate)
  • Application ratein/hr = 231 × GPH ÷ (emitter spacing × row spacing, inches) · mm/hr = L/h ÷ (spacings in m)
  • Micro-spraysin/hr = 1.604 × total GPH ÷ area (sq ft)
  • Tape flow densityGPM per 100 ft = GPH × (1,200 ÷ emitter spacing in inches) ÷ 60
  • Supply checkdesign flow = supply × margin · zones = ⌈zone GPM ÷ design flow⌉ · most emitters = ⌊design GPM × 60 ÷ emitter GPH⌋

Rows are rounded up so the bed is covered. Emitters per row are rounded down, because the last emitter has to fit inside the row.

Worked examples

A shrub bed with two emitters per plant

  1. Inputs20 shrubs, 2 emitters each, 1.0 GPH emitters; supply 8 GPM with an 80 % margin.
  2. Count and flow20 × 2 = 40 emitters, 40 GPH = 0.67 GPM.
  3. Supply8 × 80 % = 6.4 GPM design flow. One zone is plenty; the supply could run 6.4 × 60 = 384 such emitters.

A 4 × 8 ft raised bed with dripline

  1. LayoutRows 12 in apart across 4 ft = 4 rows; emitters every 12 in along 8 ft = 8 per row.
  2. Count and flow4 × 8 = 32 emitters on 32 ft of dripline; 32 × 0.9 = 28.8 GPH (0.48 GPM).
  3. Rate231 × 0.9 ÷ (12 × 12) = 1.44 in/hr, and 0.9 × 100 ÷ 60 = 1.50 GPM per 100 ft.

A 100 × 30 ft vegetable plot with drip tape

  1. LayoutRows 36 in apart: 10 rows of 100 ft = 1,000 ft of tape; 0.24 GPH emitters every 12 in = 1,000 emitters.
  2. Flow1,000 × 0.24 = 240 GPH = 4.00 GPM; 0.40 GPM per 100 ft.
  3. Rate231 × 0.24 ÷ (12 × 36) = 0.13 in/hr: slow, so tape runs for hours.

A bed that outgrows the supply

  1. Inputs150 plants × 4 emitters × 2.0 GPH on a 6 GPM supply at 80 %.
  2. Result600 emitters draw 1,200 GPH = 20.00 GPM against a 4.8 GPM design flow: split into 5 zones of up to 144 emitters.

Common emitter and dripline flows

Typical flows. Check the product for its rated flow and pressure.
ProductFlow per emitterTypical use
Point-source emitter0.5, 1, 2, 4 GPH (2, 4, 8, 16 L/h)Shrubs, trees, pots
Landscape dripline0.4–1.0 GPH every 12–24 inBeds, hedges, ground cover
Drip tape0.16–0.45 GPH every 6–12 inVegetable and crop rows
Micro-spray / jet5–30 GPHOrchards, wide root zones, sandy soil

Drip tape in 5/8-in size is the most common for row crops. Not sure which spacing to use? The emitter spacing calculator sets it from your soil.

Will the zone fit your supply?

Enter the flow your tap or meter can give and the calculator compares it with the zone. If the zone draws more than your design flow, it tells you how many zones to split it into and how many emitters of that size one zone can run. Keep drip on its own zones, separate from spray and rotor heads, because it runs much longer at much lower flow.

Very small zones (under about 0.5 GPM) need a valve and pressure regulator rated for low flow, or they may not close or regulate properly.

Application rate and your soil

For dripline and micro-sprays, the calculator gives the depth applied per hour over the bed. Pick your soil and it checks whether water lands faster than the soil absorbs it. Tight grids on clay can puddle; tape on wide rows rarely does. Turn the rate into minutes with the run time calculator.

Application rate for common dripline grids.
Grid (emitter × row)0.4 GPH0.6 GPH0.9 GPH
12 × 12 in0.64 in/hr0.96 in/hr1.44 in/hr
12 × 18 in0.43 in/hr0.64 in/hr0.96 in/hr
18 × 18 in0.29 in/hr0.43 in/hr0.64 in/hr
24 × 24 in0.16 in/hr0.24 in/hr0.36 in/hr

Mistakes to avoid

Mixing GPH and GPM

Emitters are rated per hour, supplies per minute. 40 GPH is 0.67 GPM, not 40.

Rows too long

Pressure falls along a drip line. Rows over about 100 ft of 1/2-in dripline or 300 ft of tape need a run length check.

Bigger emitters for bigger plants

Add emitters rather than using one large one. More points wet more of the root zone.

Non-PC emitters at the wrong pressure

Non-compensating emitters only give their rated flow at their rated pressure. Check real output with the emitter flow calculator.

How we build and check this calculator

Every formula on this page names its source, and the code is tested against worked cases before every update.

  • Methods from recognised sources. The application-rate relationship follows the B.C. Trickle Irrigation Manual; zoning follows the same manual and manufacturer design guides. See the sources.
  • Tested against worked cases. Seven cases run against the calculator code before every update: a shrub bed with a supply check, a raised bed, a tape plot, micro-sprays, a metric bed, a zone that outgrows its supply and a bed shorter than one spacing. All must match.
  • Honest about limits. The count assumes every emitter gives its rated flow. Long rows, low pressure and clogging change that.
  • Your entries stay on your device. The calculator runs in your browser. Nothing you type is sent anywhere; your inputs live only in the page address, so you can bookmark or share a result.
  • Corrections are welcome. If a number looks wrong, tell us. We check it against the sources, fix the page and update the date at the top.

Page history

Published. Methods, test cases and source links checked.

Questions

How many drip emitters do I need per plant?

Small plants usually need one, shrubs two, and trees several spread under the canopy. The number depends on your soil and the plant’s size. The emitter spacing calculator works it out from your soil and canopy width.

How do I convert drip GPH to GPM?

Divide by 60. 40 emitters at 1 GPH draw 40 GPH, which is 0.67 GPM. Your water supply and valves are rated in GPM, so convert before you compare.

How many emitters can one drip zone run?

Multiply your design flow in GPM by 60 to get GPH, then divide by the flow of one emitter. With 8 GPM available and an 80 % margin, a zone can run 6.4 × 60 = 384 one-GPH emitters.

Should I use dripline or individual emitters?

Dripline, with emitters built in at a set spacing, suits beds, hedges and crop rows where you want a continuous wet strip. Individual emitters suit plants spaced far apart, such as shrubs and trees, because you only water where the roots are.

What does GPM per 100 ft mean for drip tape?

It is the flow 100 feet of tape draws. Tape with 0.24 GPH emitters every 12 in uses 0.40 GPM per 100 ft. Multiply by the total footage ÷ 100 for the zone flow, and use it to compare tapes.

How fast does drip apply water?

Dripline on a tight 12 × 12 in grid at 0.9 GPH applies about 1.4 in/hr, as fast as a spray head. Tape on 36-in rows applies about 0.13 in/hr. Micro-sprays usually apply 0.5–1 in/hr.

Micro-sprays or drip?

Micro-sprays wet a wide circle, which suits sandy soil, ground covers and big root zones. Drip puts water at points or along a line and loses less to wind and evaporation. Both are low-pressure systems and go on their own zones.

Sources

  1. B.C. Ministry of Agriculture and Food, B.C. Trickle Irrigation Manual (1999), Appendix E: Equations. The emitter flow equation and the application-rate relationship AR = 1.6 × GPH ÷ area, the same as 231 × GPH ÷ (Se × Sr).
  2. B.C. Ministry of Agriculture and Food, B.C. Trickle Irrigation Manual (1999), Chapter 15: Landscape Micro Irrigation. Drip zoned separately from spray and rotor heads, and the gallons-per-plant approach for landscape drip.
  3. Oklahoma State University Extension, Drip Irrigation Systems (BAE-1511). Drip tape sizes (5/8 in most common) and tape as the usual choice for row crops.
  4. Hunter Industries, Residential System Design Guide (LIT-226). Measuring available flow and designing zones to a share of it.
  5. Emitter counts, footage, flows, GPM per 100 ft, the supply check and all unit conversions are derived on this page. The 80 % design margin is common practice, not a standard.

Links checked November 15, 2026. The application-rate constant 231 (cubic inches per US gallon) was checked against the B.C. manual’s 1.6 × GPH ÷ area form (1.604 = 231 ÷ 144).