Sprinkler Nozzle Flow Calculator
Work out how much water a sprinkler nozzle uses. Scale a catalogue rating to the pressure at your head, get the flow from an orifice size (or the size for a target flow), and find the matched flow for quarter, half and part-circle heads, including a reduced radius.
Nozzle flow calculator
How the calculator works
A nozzle is a small hole. How much water goes through it depends on the size of the hole and the pressure pushing on it.
- New pressureQ₂ = Q₁ × √(P₂ ÷ P₁), with any flow and pressure units as long as they match
- Orifice flowQ (GPM) = 29.82 × Cd × D² × √P, D in inches, P in psi
- Orifice sizeD = √(Q ÷ (29.82 × Cd × √P))
- Matched arcQ = Qfull × arc ÷ 360 × (radjusted ÷ rfull)²
- Sizes7/64 in = 0.1094 in = 2.78 mm · 1 GPM = 3.785 L/min · 1 bar = 14.5 psi
The new-pressure rule comes straight from the orifice equation: with the same nozzle, only √P changes. The arc rule keeps every head at the same precipitation rate; a shorter radius covers a smaller circle, so flow falls with the square of the radius.
Worked examples
A rotor nozzle at higher pressure
- Rating3.11 GPM at 35 psi; the head runs at 50 psi.
- Formula3.11 × √(50 ÷ 35) = 3.11 × 1.195 = 3.717.
- Result3.72 GPM, 19.5 % more than rated. Count this extra flow when you size zones.
Flow through a 3/16 in nozzle
- InputsD = 0.1875 in, 50 psi, Cd 0.96.
- Formula29.82 × 0.96 × 0.1875² × √50 = 29.82 × 0.96 × 0.03516 × 7.071.
- Result7.12 GPM.
Matched flow for a half circle turned down to 12 ft
- InputsFull circle uses 1.60 GPM at 15 ft; this head is a half circle at 12 ft.
- Formula1.60 × 180 ÷ 360 × (12 ÷ 15)² = 0.80 × 0.64.
- Result0.51 GPM keeps it matched to the full circles.
Flow at common pressures
| Pressure | Flow | Change |
|---|---|---|
| 20 psi (1.4 bar) | 1.63 GPM | −18.4 % |
| 30 psi (2.1 bar) | 2.00 GPM | rated |
| 40 psi (2.8 bar) | 2.31 GPM | +15.5 % |
| 50 psi (3.4 bar) | 2.58 GPM | +29.1 % |
| 60 psi (4.1 bar) | 2.83 GPM | +41.4 % |
Pressure below a nozzle’s range shortens the throw and leaves a dry ring near the head (the doughnut effect). Pressure above it breaks the stream into mist that drifts. Pressure-regulated heads hold the nozzle at its design pressure.
Flow by nozzle size
| Size | Diameter | 30 psi | 40 psi | 50 psi |
|---|---|---|---|---|
| 5/64 in | 1.98 mm | 0.96 GPM | 1.11 GPM | 1.24 GPM |
| 7/64 in | 2.78 mm | 1.88 GPM | 2.17 GPM | 2.42 GPM |
| 8/64 in | 3.18 mm | 2.45 GPM | 2.83 GPM | 3.16 GPM |
| 10/64 in | 3.97 mm | 3.83 GPM | 4.42 GPM | 4.94 GPM |
| 12/64 in | 4.76 mm | 5.51 GPM | 6.37 GPM | 7.12 GPM |
Matched flows by arc
For a full circle using 1.60 GPM, matched part circles use 0.40 GPM at 90°, 0.80 at 180° and 1.20 at 270°. Put these heads on one zone and each spot gets the same rate. Check the rate with the precipitation rate calculator, and add up the flows for a zone with the sprinkler zone calculator.
Mistakes to avoid
Scaling flow with pressure directly
Doubling pressure doesn’t double flow; it adds about 41 %. Use the square root.
Static pressure for running pressure
A gauge on a closed tap reads high. Measure with the zone on, at the head.
Radius screw and flow
Turning the radius down cuts flow, but the screw also distorts the stream. Use a shorter-throw nozzle for big reductions.
64ths for 128ths
Some nozzles are sized in 128ths. A “14” in 128ths is a 7/64 in nozzle; pick the right format.
How we build and check this calculator
Every formula on this page names its source, and the code is tested against worked cases before every update.
- Methods from recognised sources. The orifice equation and Cd follow irrigation extension texts; matched precipitation follows Rain Bird technical data. See the sources.
- Tested against worked cases. Eight cases run against the calculator code before every update: two pressure changes, a 7/64 in nozzle at two Cd values, a 3/16 in nozzle, sizing for 7.2 GPM, matched arcs with a reduced radius, a 4 mm metric nozzle and zero pressure. All must match.
- Honest about limits. Real nozzles have shaped orifices and stream breakers. The equation is close for round orifices; the maker’s chart is exact for theirs.
- Your entries stay on your device. The calculator runs in your browser. Nothing you type is sent anywhere; your inputs live only in the page address, so you can bookmark or share a result.
- Corrections are welcome. If a number looks wrong, tell us. We check it against the sources, fix the page and update the date at the top.
Page history
- Published. Methods, test cases and source links checked.
Questions
How does pressure affect sprinkler nozzle flow?
Flow rises with the square root of pressure, not in step with it. Raise the pressure 20 % and flow rises about 10 %; double it and flow rises about 41 %. Throw radius changes too, so check the chart.
How do I calculate flow from nozzle size?
Use Q = 29.82 × Cd × D² × √P, with Q in GPM, D in inches and P in psi. A 7/64 in nozzle at 40 psi with Cd 0.96 passes about 2.17 GPM.
What discharge coefficient (Cd) should I use?
About 0.96 for a smooth, round sprinkler nozzle, which is what irrigation texts use. Some manufacturer calculators use 0.97, and worn or sharp-edged orifices can be lower. The field accepts 0.80 to 1.00.
What nozzle size gives a certain flow?
Turn the equation around, D = √(Q ÷ (29.82 × Cd × √P)). For 7.2 GPM at 50 psi that is 0.1886 in, closest to a 12/64 in nozzle.
Why should part-circle nozzles have less flow?
A half-circle head waters half the area of a full circle, so it needs half the flow to put down the same rate. Matched-precipitation nozzles follow this; mismatched ones overwater part circles.
Is this the same as a fire sprinkler K-factor?
No. Fire sprinklers use Q = K × √P with a K-factor stamped on the head. This page is for irrigation nozzles, where makers publish flow at set pressures instead.
Where should I measure the pressure?
At the head, while the zone runs. Pressure at the meter or the tap is higher, because pipe, fittings and valves lose some on the way. The irrigation pressure calculator estimates the loss.
Sources
- LibreTexts Workforce, Irrigation Systems Management (AET 021), 11.3: Sprinkler Performance. The nozzle equation q = 29.82 Cd D² √P with Cd about 0.96, and the rule that 20 % more pressure gives about 10 % more flow.
- Kansas State University Research and Extension, Considerations for Nozzle Package Selection for Center Pivots (L908). q = Cd × 29.83 × d² × p^0.5 with discharge coefficients of 0.95–1.00.
- Rain Bird Corporation, Technical Newsletter, Spring 2001: Sprinkler Spacing. Matched precipitation, with part-circle flow in proportion to the arc.
- Rain Bird Corporation, Irrigation Design Tip: Sprinkler Spacing Patterns. Why quarter, half and full circles must put down the same rate.
- The square-root pressure relation (from the same equation with Cd and D fixed), the radius-squared adjustment, the 64ths rounding and all unit conversions are derived on this page.
Links checked November 15, 2026. The 29.82 constant was checked against both the LibreTexts and K-State forms of the equation.