Landscape Water Budget Calculator (MAWA and ETWU)

Work out a landscape water budget the way California’s Model Water Efficient Landscape Ordinance (MWELO) does. Get the maximum applied water allowance (MAWA) for residential, non-residential or existing landscapes, then enter up to ten hydrozones to see the estimated total water use (ETWU), the average ETAF and whether the design is within the allowance.

Landscape water budget calculator

Budget part
Quick picks

1Site and project

in

California: MWELO Appendix A or CIMIS. Elsewhere: your ET network or the ET calculator.

ft²

Planted and irrigated area, including any special landscape area; not hardscape.

ft²

Edible gardens, recreation turf, areas on recycled water.

See the water budget ↓

How the calculator works

A water budget compares what a landscape is allowed with what the design will use, both in gallons a year.

  • MAWAETo × 0.62 × [ETAF × LA + (1 − ETAF) × SLA]
  • Existing landscapesMAWA = ETo × 0.62 × 0.8 × LA
  • ETWUETo × 0.62 × [Σ (PF × HA ÷ IE) + SLA]
  • ETAF per hydrozonePF ÷ IE; average ETAF = Σ (ETAF × HA) ÷ Σ HA
  • 0.62gallons from one inch over one square foot (0.623, rounded in the ordinance)
  • Metriclitres = ETo (mm) × area (m²) × the same factors

ETo is in inches a year, areas in square feet. LA is the planted landscape area including any SLA; HA is each hydrozone’s area.

Worked examples

A single-family lot

  1. InputsETo 45.3 in; 3,300 ft² residential; no SLA.
  2. Result45.3 × 0.62 × 0.55 × 3,300 = 50,976 gal a year.

With an edible garden

  1. InputsETo 45.3; LA 2,400 ft² including 500 ft² SLA.
  2. ResultMAWA 45.3 × 0.62 × (0.55 × 2,400 + 0.45 × 500) = 43,393 gal. With hydrozones summing to 1,023 (PF × HA ÷ IE), ETWU is 45.3 × 0.62 × (1,023 + 500) = 42,775 gal: it complies.

Three hydrozones

  1. InputsETo 50; LA 3,000 ft²; low plants on drip 1,500 ft²; moderate on spray 1,000 ft²; high on spray 500 ft².
  2. Sum0.2 × 1,500 ÷ 0.81 + 0.5 × 1,000 ÷ 0.75 + 0.8 × 500 ÷ 0.75 = 1,570.4.
  3. ResultETWU 50 × 0.62 × 1,570.4 = 48,681 gal against MAWA 51,150: complies by 2,469 gal (4.8 %). Average ETAF 0.52.

Commercial and existing sites

  1. Non-residentialETo 40; LA 20,000 ft² with 2,000 ft² SLA; ETAF 0.45: 40 × 0.62 × (0.45 × 20,000 + 0.55 × 2,000) = 250,480 gal.
  2. Existing landscape50,000 ft², ETo 40: 40 × 0.62 × 0.8 × 50,000 = 992,000 gal.
  3. MetricETo 1,150 mm; 300 m² residential: 1,150 × 0.55 × 300 = 189,750 L (189.8 m³).

Plant factors and efficiency

Starting values used here. Choose Custom to enter a WUCOLS value for your region.
CategoryPlant factorETAF on spray (0.75)ETAF on drip (0.81)
Very low0.10.130.12
Low0.20.270.25
Moderate0.50.670.62
High0.81.070.99
Water feature1.01.331.23

A residential design averaging above 0.55 can’t comply, whatever the size. To see how plant water needs work day to day, see the water requirement calculator; for drip zone layout, the drip irrigation calculator.

Special landscape areas

Edible gardens, recreation turf and areas irrigated with recycled water are allowed their full ET. Enter the SLA as part of the landscape area and again in the SLA box; the calculator gives it ETAF 1.0 in MAWA and adds it at full ET to ETWU. Local agencies may treat recycled-water areas differently; follow yours.

When the design is over

The result names the hydrozones using the most water. Moving a 500 ft² high-water bed to low-water plants on drip cuts its use by about three quarters. Converting spray to drip lifts efficiency from 0.75 to 0.81. Once the design complies, compare real use with the allowance using the water use calculator, and price the allowance with the water cost calculator.

Outside California

The equations work anywhere with an annual ETo. Other US agencies and EPA WaterSense use similar water-budget ideas, but only local rules have legal force. Outside the US, treat the result as a design guide. Metric users get litres and cubic metres.

Mistakes to avoid

Areas that don’t add up

Hydrozones plus SLA should equal the landscape area. The calculator warns when they don’t.

Counting hardscape

Paving and decks aren’t landscape area unless they are water features.

Monthly ETo in place of annual

MAWA uses the yearly total. A monthly value makes the allowance far too small.

Dividing SLA by efficiency

The ordinance adds SLA to ETWU without dividing by IE; this calculator does the same.

How we build and check this calculator

The equations are written out plainly, and the code is tested against worked cases before every update.

  • Methods from recognised sources. The equations follow California’s MWELO; plant factors follow WUCOLS. See the sources.
  • Tested against worked cases. Seven cases run against the calculator code before every update, including a published city worksheet example reproduced exactly, an SLA case, three hydrozones, non-residential and existing landscapes, and a metric site. All must match.
  • Honest about limits. Local agencies may adopt their own versions. Check their worksheet before you submit.
  • Your entries stay on your device. The calculator runs in your browser. Nothing you type is sent anywhere; your inputs live only in the page address, so you can bookmark or share a result.
  • Corrections are welcome. If a number looks wrong, tell us. We check it against the sources, fix the page and update the date at the top.

Page history

Published. Methods, test cases and source links checked.

Questions

What are MAWA and ETWU?

MAWA, the maximum applied water allowance, is the most water a landscape is allowed in a year. ETWU, the estimated total water use, is what your design is expected to use. A design complies when ETWU is no more than MAWA.

What is ETAF?

The evapotranspiration adjustment factor, plant factor ÷ irrigation efficiency. MWELO allows an average of 0.55 for residential and 0.45 for non-residential landscapes.

What plant factors should I use?

Plant factors come from the WUCOLS plant list. Very low is 0.1, low 0.2, moderate 0.5 and high 0.8 at the middle of each range; water features count as 1.0. Choose Custom to enter a WUCOLS value for your region.

Why does drip count as 0.81 and spray 0.75?

Those are the irrigation efficiencies MWELO uses. Drip puts water closer to the roots, so each hydrozone on drip needs less water for the same plant factor.

What is a special landscape area?

Areas like edible gardens, recreation turf and areas on recycled water. MWELO allows them their full water need (ETAF 1.0), so they add to both MAWA and ETWU.

Where do I find annual ETo?

In California, the ordinance’s appendix lists ETo by city, and CIMIS has station data. Elsewhere, use your state’s ET network or our ET calculator to estimate it.

What if ETWU is over MAWA?

Change the biggest users first. Swap high-water plants for low ones, convert spray to drip, or shrink the high-water hydrozone. The result lists the hydrozones that use the most.

Sources

  1. California Department of Water Resources, Model Water Efficient Landscape Ordinance. The ordinance and guidebook behind the MAWA and ETWU equations, ETAF limits, irrigation efficiencies and Appendix A ETo values.
  2. California Department of Water Resources, Fast Facts on the State’s Model Water Efficient Landscape Ordinance. Which landscapes the ordinance covers and how applicants comply.
  3. University of California, Davis, WUCOLS — Water Use Classification of Landscape Species. Plant water use categories (very low, low, moderate, high) and plant factors by region.
  4. The equations are written out plainly on this page. The existing-landscape option (0.8 × LA) follows the MWELO provision for existing landscapes as adopted in local codes. Metric results use 1 mm on 1 m² = 1 litre.

Links checked November 15, 2026. The calculator reproduces a published city worksheet example exactly (ETo 45.3 in, 3,300 ft² residential → 50,976 gal). Outside California the method is a design guide only; EPA WaterSense uses a similar water-budget idea.