Irrigation Pumping Cost Calculator

Estimate what it costs to run an irrigation pump. Enter the lift and pressure to get energy and cost per acre-inch using the Nebraska Pumping Plant Performance Criteria, scaled by how well your plant performs — or enter horsepower and hours for a known pump. Works for electricity, diesel, propane, natural gas and gasoline, with break-even prices between them.

Pumping cost calculator

Method
Quick picks

1Energy

Your price per kWh, gallon or mcf (metric: per kWh, litre or m³). No default: enter your own.

2Pumping plant

ft

Pumping water level to the pump discharge.

psi
%

Percent of the Nebraska criteria; field-tested plants often rate below 100 %.

3Season (optional)

acres
in
See your pumping cost ↓

How the calculator works

Pumping cost comes down to how high you lift the water, how much pressure you add, how well the plant turns energy into work, and what the energy costs.

  • Total headTDH (ft) = pumping lift + psi × 2.31
  • Work per acre-inchwhp-h = 27,154 × TDH ÷ (3,960 × 60) = 0.11428 × TDH
  • Energyunits per acre-inch = whp-h ÷ (Nebraska criteria × rating)
  • Costunits × price; season = cost per acre-inch × acres × inches
  • Known pumpelectric kWh = hp × 0.7457 × hours ÷ motor efficiency; engines: hp × hours ÷ hp-h per unit
  • Break-evenprice of fuel B = price of A × criteria B ÷ criteria A

Get the lift and pressure from a pump test, or work out the head with the irrigation pump calculator.

Worked examples

Published diesel check

  1. InputsDiesel; 125 ft lift; 35 psi; 100 % rating.
  2. ResultTDH 205.9 ft; 23.53 whp-h; 1.882 gal per acre-inch. At 300 ft + 50 psi and 80 %: 4.749 gal.

Electric well

  1. Inputs200 ft + 40 psi; 85 %; $0.12 per kWh (example); 130 acres × 10 in.
  2. ResultTDH 292.4 ft; 44.42 kWh; $5.33 per acre-inch; about $6,930 for the season.

Diesel pivot well

  1. Inputs150 ft + 60 psi; 80 %; $3.80 per gallon (example); 120 acres × 8 in.
  2. ResultTDH 288.6 ft; 3.298 gal; $12.53 per acre-inch; about $12,032 a season.

Known pumps

  1. Electric40 hp, 1,000 h, 90 % motor, $0.11 per kWh: 33,142 kWh, $3,645.64.
  2. Diesel60 hp, 800 h, $3.80 per gallon: 2,881.2 gal, $10,948.38.
  3. Natural gas100 ft + 50 psi, 90 %, $4.50 per mcf: 0.444 mcf, $2.00 per acre-inch.

The Nebraska criteria

Work a well-tuned pumping plant gets per unit of energy.
EnergyUnitWater hp-hoursEngine hp-hours
ElectricitykWh0.8851.18
Dieselgallon12.516.66
Gasolinegallon8.6611.5
Propanegallon6.899.2
Natural gasmcf61.7 (or 66.7)82.2

A plant rated 80 % uses 1 ÷ 0.8 = 1.25 times the energy of a well-tuned one.

Diesel vs electric

The result lists the price of every other energy source that would give the same cost per acre-inch. Diesel at $3.80 a gallon equals electricity at about $0.27 per kWh (3.80 ÷ 14.12), propane at $2.09 and natural gas at $18.76 per mcf. If your electric rate is below the break-even, electric pumping is cheaper — before demand charges and equipment costs.

Lowering the cost

Mistakes to avoid

Static water level as lift

Use the pumping level, which is deeper. Static level understates the cost.

Assuming 100 %

Most tested plants fall short of the criteria. Enter your test result if you have one.

Comparing fuels on price per unit

A gallon and a kWh do different amounts of work. Use the break-even prices.

Forgetting demand charges

Electric bills often add a demand or horsepower charge. Add it separately.

How we build and check this calculator

Every formula on this page names its source, and the code is tested against worked cases before every update.

  • Methods from recognised sources. The criteria follow K-State and NC State Extension tables; head and horsepower follow K-State’s formula sheet. See the sources.
  • Tested against worked cases. Eight cases run against the calculator code before every update, including two published University of Nebraska diesel values, an electric and a diesel well, natural gas, two known pumps and the 14.12 diesel-to-electric factor. All must match.
  • Honest about limits. Energy only. Repairs, labour and demand charges can add a lot.
  • Your entries stay on your device. The calculator runs in your browser. Nothing you type is sent anywhere; your inputs live only in the page address, so you can bookmark or share a result.
  • Corrections are welcome. If a number looks wrong, tell us. We check it against the sources, fix the page and update the date at the top.

Page history

Published. Methods, test cases and source links checked.

Questions

What does it cost to pump an acre-inch?

It depends on lift, pressure, the fuel price and how well the plant runs. A 200-ft electric well at 40 psi and 85 % of the criteria uses about 44 kWh per acre-inch, $5.33 at $0.12 per kWh. Enter your own numbers.

Is diesel or electric cheaper for irrigation?

Compare on the same work. A gallon of diesel does 14.12 times the pumping work of a kWh under the Nebraska criteria, so diesel at $3.80 matches electricity at about $0.27 per kWh. Below that electric price, electric wins.

What are the Nebraska Pumping Plant Performance Criteria?

Benchmarks for how much pumping work (water horsepower-hours) a well-tuned plant gets from a unit of energy — 12.5 per gallon of diesel, 0.885 per kWh and so on. Plants that test below 100 % use more energy than they should.

How do lift and pressure drive cost?

Cost rises in step with total head. Each psi adds 2.31 ft, so cutting a pivot from 60 to 30 psi takes 69 ft off the head and cuts the energy for that part of the head by the same share.

How do I get my performance rating?

A pump test measures flow, head and energy used and compares them with the criteria. Many field plants test well below 100 %; below 80 %, a repair often pays for itself.

Which natural gas value should I use?

Tables list 61.7 or 66.7 whp-h per mcf depending on the heating value assumed for the gas. Use 61.7 unless your supplier’s gas is about 1,000 BTU per cubic foot, then 66.7.

Sources

  1. Kansas State University Research and Extension, Comparing Irrigation Energy Costs (MF-2360). Comparing fuels on the Nebraska criteria; a gallon of diesel gives 14.12 times the whp-h of a kWh.
  2. NC State Extension, Pumping Plant Performance. Nebraska performance standards by energy source, including 66.7 whp-h per 1,000 ft³ of natural gas.
  3. Kansas State University, Using Your Records to Locate Inefficient Pumping Plants. The criteria table with engine hp-h per unit (16.66 diesel, 11.5 gasoline, 9.2 propane, 82.2 natural gas) and the performance rating method.
  4. Kansas State University Research and Extension, Irrigation Formulas and Conversions (MF-2404). Water horsepower = GPM × TDH ÷ 3,960, 2.31 ft of head per psi and 27,154 gallons per acre-inch.
  5. Water hp-hours per acre-inch = 27,154 × TDH ÷ (3,960 × 60) = 0.11428 × TDH, the break-even prices and metric conversions are derived on this page. Your energy price is your own; the page has no default price.

Links checked November 15, 2026. The calculator reproduces published University of Nebraska diesel values (125 ft + 35 psi → 1.88 gal per acre-inch; 300 ft + 50 psi at 80 % → 4.74–4.75 gal).