Center Pivot Calculator
Find how much water one revolution of a center (centre) pivot applies — gross and net — along with the acres under it, gpm per acre and the average application rate. Get the revolution time from hours, from the percent timer, or from a stake speed test, or enter a target depth to get the hours per revolution and the percent-timer setting.
Center pivot calculator
How the calculator works
A pivot’s depth per pass depends on its flow, how long a revolution takes, and how many acres it covers.
- Areaacres = π × (machine length + overhang)² ÷ 43,560 × arc ÷ 360
- Gross depthin = gpm × hours × 60 ÷ (acres × 27,154); net = gross × efficiency
- Percent timerhours = hours at 100 % × 100 ÷ timer % (× arc ÷ 360)
- Speed testminutes = 2π × wheel-track distance × arc ÷ 360 × test minutes ÷ test distance
- Timer for a depthhours = depth × acres × 27,154 ÷ (gpm × 60); timer % = hours at 100 % ÷ hours × 100
- Average ratein/hr = gpm × 60 ÷ (acres × 27,154)
- End-gun weightingarea = base × (1 − f) + area with gun × f, f = share of the arc with the gun on
Worked examples
A 125-acre pivot
- Inputs800 gpm; 48 h a revolution; 85 %.
- Result800 × 48 × 60 ÷ (125 × 27,154) = 0.68 in gross; 0.58 in net.
A speed test
- InputsWheel track 1,280 ft from the pivot; 200 ft in 32 min.
- Result2π × 1,280 × 32 ÷ 200 = 1,286.8 min (21 h 27 min).
Timer for 1 inch
- Inputs1,300 ft with an end gun (75 ft overhang); 850 gpm; 20 h at 100 %.
- Area and rate136.35 acres; 6.23 gpm per acre; 0.0138 in/hr.
- Result0.28 in at full speed; 1 in needs 72.6 h, a 27.5 % timer. At 40 % the pass takes 50 h and puts on 0.69 in gross (0.59 in net).
Half circle and metric
- Half circle1,300 ft + 40 ft, 180°, 600 gpm, 24 h: 64.75 acres; 0.49 in.
- Metric400 m + 12 m, 60 L/s, 30 h: 53.33 ha; 12.2 mm.
Percent-timer table
| Timer | Hours a revolution | Gross depth |
|---|---|---|
| 100 % | 20.0 | 0.28 in |
| 80 % | 25.0 | 0.34 in |
| 60 % | 33.3 | 0.46 in |
| 50 % | 40.0 | 0.55 in |
| 40 % | 50.0 | 0.69 in |
| 30 % | 66.7 | 0.92 in |
| 20 % | 100.0 | 1.38 in |
The calculator builds this table for your pivot under every result.
Depth and runoff
On flat ground with good intake, 0.5–0.8 in a pass is common; on slopes or tight soils, 0.3–0.5 in. Above about 1 in, the outer spans may run off because they apply water fastest. To set the depth, see how much the crop used since the last pass with the ET calculator or plan passes with the irrigation schedule calculator. A light system (under about 5 gpm per acre) may not keep up; check it with the system capacity calculator.
Pivot acres and end guns
Water reaches past the last tower: about 40 ft without an end gun and 75 ft with one. Use your sprinkler chart’s wetted radius if you have it. An end gun that runs only in the corners adds area for part of the circle; the advanced fields weight it by the share of the arc it runs. To inject fertilizer through the pivot, take the hours and acres to the fertigation calculator. The energy cost of a pass comes from the pumping cost calculator.
Mistakes to avoid
Asking for less than full speed gives
No timer setting goes above 100 %. If the target is below the depth at full speed, lower the flow or accept the minimum.
Full-circle hours on a part circle
Panel hours at 100 % are for 360°. The calculator scales them for your arc.
Machine length as the radius
Add the wetted overhang; it adds several acres on a quarter-mile pivot.
Very low timer settings
Below about 5 %, start-stop timing makes depth less predictable and runoff likely.
How we build and check this calculator
Every formula on this page names its source, and the code is tested against worked cases before every update.
- Methods from recognised sources. Calibration methods follow SDSU and WSU Extension; depth bands follow University of Tennessee Extension. See the sources.
- Tested against worked cases. Nine cases run against the calculator code before every update, including the SDSU depth, speed-test and end-gun examples, the Tennessee table, a timer setting, a half circle, a metric pivot and a target below the full-speed depth. All must match.
- Honest about limits. Corner arms change the area as they swing; use the measured area for those.
- Your entries stay on your device. The calculator runs in your browser. Nothing you type is sent anywhere; your inputs live only in the page address, so you can bookmark or share a result.
- Corrections are welcome. If a number looks wrong, tell us. We check it against the sources, fix the page and update the date at the top.
Page history
- Published. Methods, test cases and source links checked.
Questions
How many inches does my pivot put on?
Gross inches = gpm × hours per revolution × 60 ÷ (acres × 27,154). An 800 gpm pivot on 125 acres taking 48 hours puts on 0.68 in gross, about 0.58 in net at 85 % efficiency.
How do I set a percent timer for 1 inch?
Find the depth at 100 % (the fastest the pivot goes). Timer % = depth at 100 % ÷ target depth × 100. A pivot that puts on 0.28 in at 100 % needs about 27.5 % for 1 inch.
How do I time a pivot with stakes?
Place two stakes along the outer wheel track, time how long the tower takes to go from one to the other, and measure the distance. Revolution minutes = 2π × wheel-track radius × minutes ÷ distance.
How many acres are under a quarter-mile pivot?
A 1,300 ft machine wets out about 40 ft further without an end gun (about 129.5 acres for a full circle) and about 75 ft with one (about 136 acres).
What gpm per acre does a pivot need?
Commonly about 5–7 gpm per acre for full irrigation, depending on region, soil and crop. Below about 5 the pivot may not keep up at peak.
Why do the outer spans run off?
The outer spans cover the most ground, so their sprinklers apply water fastest. A deep, slow pass can exceed what the soil takes in there, even when the average depth seems modest.
What is the difference between gross and net depth?
Gross is what leaves the nozzles. Net is what reaches the root zone after evaporation and drift; net = gross × efficiency.
Sources
- South Dakota State University Extension, Chemigation — Calibrating Systems for Center Pivot Irrigation (FS 863). Rotation time from a stake speed test, depth from gpm and rotation time, partial circles and end-gun area weighting.
- Washington State University, Pivot Full Rotation Time. Full-rotation time and percent-timer relations used in WSU’s pivot calculators.
- University of Tennessee Extension, Understanding Center Pivot Application Rate (W809). Depth against revolution time at 6.0 gpm per acre, and why the outer spans apply water fastest; depth bands for flat and sloping ground.
- Kansas State University Research and Extension, Irrigation Formulas and Conversions (MF-2404). Pivot acreage with the wetted overhang (about 40 ft beyond the last tower, 75 ft with an end gun).
- The timer and depth formulas, minimum depth at full speed and the timer table are derived on this page with exact π and 27,154.29 gallons per acre-inch.
Links checked November 16, 2026. The page reproduces the SDSU examples (0.58 in net; 1,286.8 min, which SDSU rounds to 1,286 with π = 3.14) and the Tennessee table (0.40 in at 30 h at 6 gpm per acre). SDSU’s end-gun formula line prints 135.3 acres; its stated 129.5 acres needs 137.3, which is what the page uses.