Weir and Flume Flow Calculator
Turn the head on a sharp-crested weir (rectangular, 90° V-notch or Cipolletti) or a Parshall flume (1 in to 50 ft) into flow in cfs, gpm, litres per second, acre-inches and acre-feet a day and miner’s inches — or find the head to expect for a target flow. Every result is checked against the U.S. Bureau of Reclamation limits, and flumes against submergence.
Weir and flume flow calculator
How the calculator works
A weir or flume turns a depth you can read into a flow you can’t see. Each device has its own rating equation.
- Contracted rectangularQ = 3.33 (L − 0.2h) h^1.5
- Suppressed rectangularQ = 3.33 L h^1.5
- 90° V-notchQ = 2.49 h^2.48
- CipollettiQ = 3.367 L h^1.5
- ParshallQ = C × Ha^n (Table 8-6); 2–8 ft: Q = 4W × Ha^(1.522 W^0.026)
- UnitsQ in cfs; h, L and W in feet; gpm = cfs × 448.83
Metric heads and lengths are converted to feet, the equations applied, and the flow returned in L/s and m³/h.
Worked examples
Weirs
- V-notch0.2 ft: 0.046 cfs (20.6 gpm); 0.5 ft: 0.446 cfs (200 gpm); 1.25 ft: 4.33 cfs.
- Cipolletti1.5 ft crest, 0.4 ft head: 1.278 cfs (573.5 gpm), within range (0.4 ≤ 0.5).
- Rectangular, 2 ft, 0.5 ftcontracted 2.237 cfs; suppressed 2.355 cfs — end contractions cut the effective length by 0.1 ft.
Parshall flumes
- 6 ft at 3.5 ft176.9 cfs.
- 2 ft at 1.5 ft15.00 cfs. 3 in at 0.5 ft 0.339 cfs (152 gpm). 1 in at 0.2 ft 0.028 cfs.
- Submerged1 ft flume, Ha 1.0 ft, Hb 0.75 ft: free-flow 3.95 cfs, but 75 % is over the 70 % limit — the true flow is lower.
Head for a flow and metric
- V-notch for 0.446 cfshead 0.500 ft (6.00 in).
- Metric Cipolletti0.5 m crest, 0.15 m head: 1.907 cfs = 54.0 L/s.
Parshall flume sizes
| Throat | C | n | Free-flow limit (Hb/Ha) |
|---|---|---|---|
| 1 in | 0.338 | 1.55 | 50 % |
| 3 in | 0.992 | 1.55 | 50 % |
| 6 in | 2.06 | 1.58 | 60 % |
| 9 in | 3.07 | 1.53 | 60 % |
| 1 ft | 3.95 | 1.55 | 70 % |
| 2–8 ft | 4W × Ha^(1.522 W^0.026) | 70 % | |
| 10–50 ft | 39.38–186.88 | 1.60 | 80 % |
Installation limits
- Head at least 0.2 ft, or the nappe clings to the plate and readings run high.
- Rectangular and Cipolletti: head no more than one-third of the crest length.
- Crest at least 2 × the maximum head above the channel floor (3 × for suppressed weirs), sides 2 heads from the banks.
- Head read at least 4 × the maximum head upstream, in calm water; downstream water at least 0.2 ft below the crest.
Every result says whether the head is within these limits. Only 90° V-notches are supported; other angles need a calibrated rating.
Irrigation flow units
1 cfs is 448.83 gpm, about one acre-inch an hour or two acre-feet a day. Miner’s inches depend on the state: 40, 50 or 38.4 per cfs. Convert any flow with the acre-inch converter. Use the measured flow to plan a furrow set with the furrow irrigation calculator, or check it against a field’s need with the system capacity calculator. For a home supply, the available flow calculator fits better.
Mistakes to avoid
Reading the head at the crest
Water drops as it nears the crest. Read at least four heads upstream.
A submerged flume
If the downstream water backs up past the limit, the free-flow result is too high.
Inches as feet
A staff gauge in inches entered as feet gives 12 times the head. Pick the right unit.
A dull or tilted crest
Nicks, algae and a sloping crest all change the rating. Keep it clean, sharp and level.
How we build and check this calculator
Every equation on this page is the U.S. Bureau of Reclamation’s, and the code is tested against worked cases before every update.
- Methods from the standard reference. Weir and flume equations, limits and miner’s inch definitions follow the USBR Water Measurement Manual. See the sources.
- Tested against worked cases. Twelve cases run against the calculator code before every update: V-notch, Cipolletti and rectangular weirs, four Parshall sizes, a submerged flume, a metric weir, a head-for-flow case and a head too high for the crest. All must match.
- Honest about limits. Submerged-flow corrections and other flume types aren’t calculated here.
- Your entries stay on your device. The calculator runs in your browser. Nothing you type is sent anywhere; your inputs live only in the page address, so you can bookmark or share a result.
- Corrections are welcome. If a number looks wrong, tell us. We check it against the sources, fix the page and update the date at the top.
Page history
- Published. Methods, test cases and source links checked.
Questions
How do I measure flow with a weir?
Read the head — the height of the water above the crest — at a point at least four times the maximum head upstream, then apply the weir’s equation. The crest must be level and sharp and the water must fall freely, with air under the nappe.
What are the weir formulas?
In cfs with heads in feet, contracted rectangular 3.33 (L − 0.2h) h^1.5, suppressed rectangular 3.33 L h^1.5, 90° V-notch 2.49 h^2.48 and Cipolletti 3.367 L h^1.5, as given by the U.S. Bureau of Reclamation.
How does a Parshall flume work?
The narrowing throat and dropping floor speed the water up, so the upstream depth (Ha) relates to flow by Q = C·Ha^n for each throat size. It handles sediment better than a weir and loses less head.
What is the difference between free and submerged flow?
In free flow the water drops away below the device. When the downstream water backs up (Hb high against Ha), the flume is submerged and the free-flow equation overstates the flow. Limits are 50 % for 1–3 in flumes up to 80 % for the large ones.
Weir or flume, which should I use?
Weirs are cheap and accurate in clean water with enough drop. Flumes need less drop and pass sediment, so they suit ditches with silt or little fall.
What is a miner’s inch?
An old flow unit still used in western water rights — 1/40 cfs in Arizona, California, Montana, Nevada and Oregon, 1/50 cfs in Idaho, Kansas, Nebraska, New Mexico, North Dakota and Utah, and 1/38.4 cfs in Colorado.
My staff gauge reads in inches. Can I use it?
Yes. Choose inches for the head unit. 6 in is 0.5 ft.
Sources
- U.S. Bureau of Reclamation, Water Measurement Manual, Chapter 7 — Standard Contracted Rectangular Weirs. The Francis equation 3.33 (L − 0.2h) h^1.5 and its limits (head not over one-third of the crest length, crest at least 2 heads above the approach floor).
- U.S. Bureau of Reclamation, Water Measurement Manual, Chapter 7 — Cipoletti Weir. Q = 3.367 L h^1.5 with about ±5 % accuracy; head measured at least four heads upstream.
- U.S. Bureau of Reclamation, Water Measurement Manual, Chapter 8 — Parshall Flumes. Free-flow equations Q = C·Ha^n by throat width (Table 8-6), the 2–8 ft formula behind table A8-12, and submergence limits.
- U.S. Bureau of Reclamation, Water Measurement Manual — Conversion factors. Flow conversions and miner’s inch definitions by state.
- The 90° V-notch form 2.49 h^2.48 and the general limits (head at least 0.2 ft; fully contracted V-notch up to 1.25 ft) are from the same manual’s weir chapter. Solving for head inverts each equation (bisection for the contracted weir). Conversions — gpm = cfs × 448.83; acre-inches a day = cfs × 86,400 ÷ 3,630 — are derived on this page.
Links checked November 16, 2026. For 2–8 ft flumes the page uses the formula behind the USBR tables; a worked example using Table 8-6’s rounded exponent gives 175.9 cfs for a 6-ft flume at 3.5 ft where the formula gives 176.9 (0.6 % more).